KB 405743 - Cisco Nexus switch(9312) Unexpected Cluster Connectivity Loss

KB 405743 - Cisco Nexus switch(9312) Unexpected Cluster Connectivity Loss


1. Summary

This article describes an incident where a faulty fan module in a Cisco Nexus leaf switch caused physical-layer instability, leading to intermittent connectivity loss for critical cluster nodes. The issue resulted in a cluster-wide access outage. This article documents the symptoms, root cause analysis, and corrective actions to prevent a recurrence.

Key Findings:
 Recurrent hardware failures of Fan module 1 (Fan1) were directly correlated with physical interface flaps on the connected ports (Ethernet1/27 and Ethernet1/43). The issue was environmental/hardware-related and not due to software, configuration, or traffic congestion.

2. Symptoms

During the incident window, the following symptoms were observed:

  • Intermittent Connectivity:
     Critical cluster nodes connected to ports Ethernet1/27 and Ethernet1/43 experienced repeated, unpredictable loss of network connectivity.
  • Service Disruption:
     The connectivity loss caused a cluster-wide access outage, impacting dependent applications and services.
  • Switch Log Messages:
     The following error messages were observed in the switch logs, often preceding the interface flaps:
    • %PLATFORM-1-PFM_ALERT: FAN_BAD: fan1
  • Interface Flapping:
     The affected interfaces (Ethernet1/27, Ethernet1/43) showed:
    • Link-down events (physical link failure).
    • Speed renegotiation (e.g., dropping from 10 Gbps to 100 Mbps and back).
    • Duplex resets.
    • Multiple flaps within a short period.

3. Environment

  • Device:
     Cisco Nexus Leaf Switch (Hostname: T10PHGXINLFSWXX)
  • Connected Assets:
     Two critical cluster nodes.

4. Root Cause Analysis

The root cause was a hardware failure of Fan Module 1 (Fan1) .

  • Primary Cause:
     The faulty fan module created an unstable hardware environment, potentially through thermal stress or electrical issues. This instability directly impacted the physical-layer integrity of nearby components or backplane connections, triggering link flaps on Ethernet1/27 and Ethernet1/43.
  • Contributing Factor:
     The fan's status oscillated between 'OK' and 'FAIL', indicating an intermittent hardware fault that was difficult to diagnose without close log correlation.

Exclusions:
 A thorough analysis of show tech-support logs and buffer statistics confirmed the issue was not caused by:

  • Micro-burst traffic or congestion.
  • Buffer exhaustion or ECN marking.
  • Recent configuration or software changes.
  • Issues on other interfaces or the management plane.

5. Scope of Impact

  • Direct Impact:
     Loss of network connectivity for two critical nodes connected to the affected interfaces.
  • Business Impact:
     Cluster-wide service disruption, operational risk to dependent applications. No data loss was reported.

6. Resolution and Corrective Actions

The following steps were recommended by Cisco TAC to resolve the immediate issue and prevent its recurrence.

Immediate Remediation Steps

  1. Reseat/Replace Cables:
     Reseat the fiber or copper cables connected to Ethernet1/27 and Ethernet1/43 to ensure a secure connection.
  2. Reseat/Replace Optics:
     Reseat or replace the transceiver modules (SFPs) on both ends of the affected links.
  3. Check Remote End:
     Inspect the interfaces and optics on the remote devices connected to these ports for any errors or instability.

Permanent Fix

  1. Replace Faulty Hardware:
    Replace Fan Module 1 (Fan1) via RMA (Return Material Authorization). This is the definitive fix to eliminate the source of hardware instability.
  2. Post-Replacement Monitoring:
     After the fan replacement, closely monitor the following for at least 24-48 hours:
    • System logs for any FAN_BAD or other environmental alerts.
    • Interface status and error counters for Ethernet1/27 and Ethernet1/43.
    • Overall switch health and environmental data (temperature, voltage).

7. Preventive Measures

To prevent similar incidents in the future, the following recommendations should be implemented:

  • Proactive Environmental Monitoring:
     Enable and actively monitor SNMP traps and system logs for hardware alerts (like FAN_BAD, PFM_ALERT, temperature warnings). Integrate these alerts into a network monitoring system (e.g., SolarWinds, PRTG, Nagios).
  • Immediate Alert Escalation:
     Treat repeated hardware environmental alerts as high-priority incidents. Do not assume a temporary fan recovery means the issue is resolved.
  • Scheduled Physical Inspections:
     Periodically inspect and clean optical cables and transceivers on all critical links as part of routine maintenance.
  • Design for Redundancy:
     Where possible, architect critical node connections with redundancy (e.g., using NIC teaming, vPC, or dual-homed connections) to mitigate the impact of a single point of failure like a switch port or module.

  • Cisco Documentation: [Link to Cisco Nexus Platform-Specific Hardware Troubleshooting Guide Cisco Nexus 93120TX Switch - Cisco]
  • Cisco Documentation: [Link to Understanding and Monitoring Environmental Alerts on Nexus Switches]

    • Recent Articles

    • KB-630208 | How to use Find and Locate to search for files in Linux

      Purpose To provide Linux administrators and Field Engineers with guidance on using the find and locate utilities to efficiently search for files and directories within a Linux filesystem based on criteria such as name, type, size, timestamps, ...
    • KB-630164 | How to use rsync to Synchronize Files

      Purpose To provide a clear and practical procedure for using the rsync utility to synchronize files and directories between local systems and remote hosts, including push and pull operations, while preserving file attributes and optimizing data ...
    • KB-630107 | How to create a Linux swap file

      Purpose To provide Field Engineers and Linux administrators with a standardized procedure for creating, configuring, and validating a Linux swap file. This procedure helps ensure sufficient virtual memory is available when physical RAM is exhausted ...
    • MSI All-in-One (AIO) PC – Physical Damage Policy for Warranty Claims

      MSI All-in-One (AIO) PC – Physical Damage Policy for Warranty Claims MSI's standard warranty does not cover physical or accidental damage to an All-in-One (AIO) PC. If the damage is determined to be caused by external factors rather than a ...
    • KB 134833 - Troubleshooting NVSM Alert NV-CPU-XX – Unrecoverable CPU Internal Error

      Purpose This document provides a general troubleshooting procedure for the NVIDIA System Management (NVSM) alert NV-CPU-XX, which indicates that a CPU has reported an internal error. The article outlines how to verify whether the alert represents an ...
    • Popular Articles

    • CP Plus Camera and NVR Configuration

      NVR Configuration The CP Plus Pro Series of NVRs have been meticulously designed for providing you with upgraded performance and higher recording quality in your IP video surveillance solution. The robust processor that has been inculcated in this ...
    • KB 775235 - Kerberos Authentication – Overview

      What is Kerberos? Kerberos is a secure authentication method used in our Active Directory (AD) environment (mbuzztech.com). It allows users to: Access multiple systems without re-entering passwords (Single Sign-On – SSO) Log in once Where We Use It ...
    • How to Remove and Reinstall NVIDIA Drivers on Ubuntu

      This article provides step by step guide to completely remove existing NVIDIA drivers and reinstall specific version of the NVIDIA driver on the Ubuntu system Prerequisites Administrative (sudo) access to the Ubuntu system. Internet access to ...
    • KB 692001 - Personal Computers and Servers - Classification and Point of Contact

      We can classify the computers that MBUZZ handles based on their form-factor as below: Tower Workstations, Desktops, Gaming PCs and SFF (Small form factor) PCs fall under this category. These are computers people would use on a desk and rarely move. ...
    • KB 298031 - M.2 SSD Tier List

      The sequential read and write speeds, which are usually the most advertised number, are not a proper benchmark of real-world performance or the quality of an SSD. This article categorizes and tiers SSDs based on factors like the type of NAND flash, ...