KB 579132 - Fan Speed Warning - Troubleshooting Guide

KB 579132 - Fan Speed Warning - Troubleshooting Guide

Purpose

Provide guidance for engineers to investigate and respond to Fan Speed Warning alerts generated by the monitoring system.

This KB article ensures that engineers follow a consistent troubleshooting procedure when cooling-related alerts occur.



When to Use

Use this KB when the monitoring system triggers the alert:

Fan Speed Warning

This alert indicates that fan speed has dropped to 2000 RPM or below, which may indicate a cooling issue.


What the Alert Is

The Fan Speed Warning alert occurs when the system detects that a server fan is running at or below the threshold value.

Condition

Fan Speed ≤ 2000 RPM

This may indicate:

  • Fan degradation

  • Dust accumulation

  • Airflow obstruction

  • Early stage fan failure


Summary

Failing or underperforming fans directly impact system cooling.

If not addressed, this may lead to:

  • Increased system temperature

  • CPU or GPU thermal throttling

  • Thermal shutdown of the node

Early detection allows preventive maintenance before the issue becomes critical.


Severity

P4 – Low Impact

This is a warning alert and does not immediately impact system operation, but it should be monitored and investigated.


L1 Engineer Actions

Follow these steps when the alert is received.

Step 1 – Log Alert Details

Record the alert information from the monitoring system.

Capture:

  • Node hostname

  • Alert timestamp

  • Fan speed reading

  • Alert severity


Step 2 – Monitor Alert Behavior

Check if the alert is persistent or transient.

If the fan speed returns to normal, continue monitoring.


Step 3 – Escalate if Alert Persists

If the alert continues:

  • Inform the L2 engineer

  • Create an internal support ticket


Step 4 – Update Issues Tracking

After confirmation with L2:

  • Add the incident to the Issues Master Sheet for tracking and reporting.


L2 Engineer Actions

Step 1 – Verify via BMC

Access the BMC / IPMI interface and verify fan sensor readings.

Check:

  • Fan RPM values

  • Fan health status

  • Hardware logs

Example command:

Note: if we need to run "ipmitool" command check server connectivity from the source machine and ipmi executable file or ipmi package must be installed in the same source machine. 
ipmitool sdr type fan

Step 2 – Identify Failed Fan

Determine which fan module has failed.

Check:

  • Fan ID

  • RPM readings

  • Sensor status

Step 3 – Plan Preventive Maintenance

If the fan continues to run below optimal speed:

  • Schedule preventive maintenance

  • Clean the server or replace the fan module if needed

Step 4 – Check for Dust or Airflow Blockage

Inspect the physical server if required.

Verify:

  • Dust accumulation

  • Blocked air vents

  • Proper airflow inside the rack

Step 5 – Try Physical Reseating the Fan

If the server supports hot-swappable fans:

  1. Remove the faulty fan module

  2. Reinsert the fan properly

  3. Verify the fan is detected again

Step 6 – Replace Faulty Fan

If reseating does not resolve the issue, replace the fan module.

Step 7 – Escalate to OEM

If the issue persists:

  • Collect hardware logs

  • Record node serial number

  • Capture sensor output

Open a support case with the OEM vendor.

    • Related Articles

    • KB 579052 - CPU Temperature Warning - Troubleshooting Guide

      Purpose Provide a troubleshooting guide for engineers when a CPU Temperature Warning alert is triggered on a Node/Server. This KB helps engineers quickly identify the issue and perform initial remediation before escalation. When to Use Use this KB ...
    • KB 579092 - Fan Speed Critical - Troubleshooting Guide

      Purpose Provide a troubleshooting guide for engineers when a Fan Speed Critical alert is generated on a server node. This article helps engineers quickly identify cooling issues and perform corrective actions to prevent overheating and potential ...
    • KB 021273 - Network Speed IB Alert - Troubleshooting Guide

      Purpose This document provides a standardized approach for handling and troubleshooting the Network Speed – IB alert, including L1 and L2 actions, escalation process, and resolution guidelines. Alert Name Network Speed IB Alert Description This alert ...
    • KB 715314 - ZFS Pool Capacity Warning Alert - Troubleshooting Guide

      Purpose This document provides a standardized approach for handling and troubleshooting the ZFS Pool Capacity Warning alert, helping L1 and L2 engineers prevent storage exhaustion and maintain system stability. Alert Name ZFS Pool Capacity Warning ...
    • KB 511966 - BeeGFS Capacity Warning – Troubleshooting Guide

      Purpose Provide a standard troubleshooting procedure for engineers when a BeeGFS Capacity Warning alert is triggered in the cluster. This guide ensures engineers follow consistent investigation and escalation steps. When to Use Use this KB when the ...
    • Recent Articles

    • KB-630208 | How to use Find and Locate to search for files in Linux

      Purpose To provide Linux administrators and Field Engineers with guidance on using the find and locate utilities to efficiently search for files and directories within a Linux filesystem based on criteria such as name, type, size, timestamps, ...
    • KB-630164 | How to use rsync to Synchronize Files

      Purpose To provide a clear and practical procedure for using the rsync utility to synchronize files and directories between local systems and remote hosts, including push and pull operations, while preserving file attributes and optimizing data ...
    • KB-630107 | How to create a Linux swap file

      Purpose To provide Field Engineers and Linux administrators with a standardized procedure for creating, configuring, and validating a Linux swap file. This procedure helps ensure sufficient virtual memory is available when physical RAM is exhausted ...
    • MSI All-in-One (AIO) PC – Physical Damage Policy for Warranty Claims

      MSI All-in-One (AIO) PC – Physical Damage Policy for Warranty Claims MSI's standard warranty does not cover physical or accidental damage to an All-in-One (AIO) PC. If the damage is determined to be caused by external factors rather than a ...
    • KB 134833 - Troubleshooting NVSM Alert NV-CPU-XX – Unrecoverable CPU Internal Error

      Purpose This document provides a general troubleshooting procedure for the NVIDIA System Management (NVSM) alert NV-CPU-XX, which indicates that a CPU has reported an internal error. The article outlines how to verify whether the alert represents an ...
    • Popular Articles

    • CP Plus Camera and NVR Configuration

      NVR Configuration The CP Plus Pro Series of NVRs have been meticulously designed for providing you with upgraded performance and higher recording quality in your IP video surveillance solution. The robust processor that has been inculcated in this ...
    • KB 775235 - Kerberos Authentication – Overview

      What is Kerberos? Kerberos is a secure authentication method used in our Active Directory (AD) environment (mbuzztech.com). It allows users to: Access multiple systems without re-entering passwords (Single Sign-On – SSO) Log in once Where We Use It ...
    • How to Remove and Reinstall NVIDIA Drivers on Ubuntu

      This article provides step by step guide to completely remove existing NVIDIA drivers and reinstall specific version of the NVIDIA driver on the Ubuntu system Prerequisites Administrative (sudo) access to the Ubuntu system. Internet access to ...
    • KB 692001 - Personal Computers and Servers - Classification and Point of Contact

      We can classify the computers that MBUZZ handles based on their form-factor as below: Tower Workstations, Desktops, Gaming PCs and SFF (Small form factor) PCs fall under this category. These are computers people would use on a desk and rarely move. ...
    • KB 298031 - M.2 SSD Tier List

      The sequential read and write speeds, which are usually the most advertised number, are not a proper benchmark of real-world performance or the quality of an SSD. This article categorizes and tiers SSDs based on factors like the type of NAND flash, ...