Purpose

This article explains how to configure and synchronize the Date & Time on ASUS HGX servers using the ASMB11‑iKVM (BMC) interface. This ensures that all HGX servers synchronize their time with the NTP servers configured on Head Node 1 and Head Node 2.

Scope

  • ASUS HGX servers

Prerequisites

  • BMC IP address reachable from the management network

  • Admin credentials 

  • Primary and secondary NTP server IPs (configured on Head Node 1 and Head Node 2)

Procedure

Step 1: Log in to BMC

  1. Open a browser and navigate to the BMC IP address of the HGX server.

  2. Log in using administrator credentials.


Step 2: Navigate to Date & Time Settings

  1. From the left navigation pane, click Settings.

  2. Select Date & Time from the settings menu.


Step 3: Configure Time Zone and NTP Servers

  1. Scroll down and select the appropriate Time Zone (example: Asia/Dubai).

  2. Enable Automatic NTP Date & Time and Configure the NTP servers as follows: 

    1. Primary NTP Server: IP address of Head Node 1

    2. Secondary NTP Server: IP address of Head Node 2

    3. Click Save.



Step 4: Post Configuration

  1. When prompted that the session will close, click OK to proceed.

  2. Close the browser session as instructed.


Step 5: Reconnect and Verify

  1. Reopen a new browser session.

  2. Log back in to the BMC.

  3. Navigate to Settings --> Date & Time.

  4. Verify:

    • Time zone is correct

    • NTP is enabled

    • Time is synchronized correctly


    • Related Articles

    • How to Configure DNS on NetApp E-Series via SANtricity Manager

      Purpose This article describes how to configure DNS servers on NetApp E-Series storage enclosures using the web-based BMC interface. Proper DNS configuration ensures successful name resolution for services such as NTP, AutoSupport, SMTP, and Syslog. ...
    • GPU vBIOS Verification Across HGX Nodes

      1. Purpose This document provides a procedure to verify GPU vBIOS versions across all HGX nodes in the cluster using an automated script. The script connects to each node from the login node using passwordless SSH and retrieves the GPU vBIOS version ...
    • SOS Report collection from NetApp OSS Servers

      Purpose This article details the process of generating and collecting SOS Reports from NetApp OSS Servers. These reports are often required by the NetApp Support Team for detailed analysis and troubleshooting. Scope Applicable to: NetApp OSS Servers ...
    • How to update Mellanox ConnectX-7 NICs Firmware on OSS Servers

      1. Purpose This article describes the procedure to upgrade the Mellanox ConnectX-7 network adapter firmware on the affected OSS servers to version 28.45.1200 in order to ensure compatibility, stability, and optimal performance. 2. Scope This ...
    • How to Connect GNS3 (Windows) to a Remote Server

      Purpose This article explains how to connect GNS3 installed on Windows to a remote GNS3 server.This is useful when the remote server has more CPU and RAM. Connecting to a remote server helps when your local computer does not have enough CPU or RAM to ...